Main Feature
*32-channel high-speed design, output up to 40-120 bottles per minute
*Photoelectric counting sensor, counting accuracy up to ≥99.8%
*Support counting setting from 8-9999 pieces for each bottle
*Suitable for 10-500ml round & square plastic bottles
*304 stainless-steel contact parts, comply with production hygiene requirement
*CE certified, certificate No. TTC-22-0103/01/01
*Stable running, easy operation and maintenance
*Custom counting solutions are supported for special products
Main Technical Parameter:
Model | YL-32 |
Production rate | 10-100 bottles/min |
Product range | Size 5# to 00# capsules, soft capsules, Ø6-26 mm round tablets, shaped tablets, and sugar-coated tablets |
Count per bottle | 2-9999 pieces |
Vibration stages | 3 |
Applicable bottles | 10-500 mL round or square bottles (standard discharge-port diameters: 22 mm and 28 mm) |
Maximum bottle height | ≤160 mm |
Accuracy | ≥99.5% |
Hopper volume | Approximately 90 L |
Air pressure | 0.6 MPa |
Power supply / rated power | 380 V, 50 Hz / 1.3 kW |
NW/GW | 720 kg |
Machine dimensions (L × W × H) | 240 × 180 × 170 cm |
Remarks | Production speed depends on the product type, size, specification, and count per bottle. |

1 | Infeed hopper |
2 | Electromagnetic vibrating trays |
3 | Touch screen |
4 | Emergency-stop switch |
5 | Bottle-stop solenoid valve |
6 | Conveyor |
7 | Machine frame |
8 | Adjustable foot |
9 | Photoelectric sensor |
10 | Discharge port |
11 | Lifting mechanism |
12 | Bottle-presence sensor |
The counting-channel arrangement is shown below:

3 Parameter Settings
Connect the power supply and turn on the main power switch. The main control screen appears as shown below.

Main control screen
01. COUNT SET: Sets the required number of pieces per bottle.
02. YIELD: Displays the accumulated production quantity. Stop the machine before touching YIELD RST to reset the value.
03. SPEED: Displays the current production speed in bottles per minute.
04. COUNT1 to COUNT4: Display the count for each lane. Stop the machine before touching COUNT RST to reset the lane counters.
05. START: Starts automatic operation.
06. STOP: Stops automatic operation.
Main screen controls and menu
07. VIBRATE+ and VIBRATE-: Fine-tune the feed vibration output.
08. RUN, ALARM, and ESTOP BLOCK: Display the running, alarm, and emergency-stop interlock status.
09. CONVEYOR: Turns the conveyor command on or off.
10. SYSTEM, MENU, TEST, EXAMINE, and RECIPE: Open the corresponding pages from the bottom navigation bar.
11. CHINESE and ENGLISH: Change the HMI display language.
12. MENU: Touch MENU to open the parameter selection page shown below.

Menu screen
Select IR, VIBRATE, BOTTLE, ABANDON, SHAKE, CONTROL, GATE SET, or FACTORY to open the required setting page. Touch SAVE after making an approved parameter change.
A IR Settings

IR setting screen
FILTER: Filters short or unwanted sensor signals. Adjust this value only after checking the counting accuracy.
TRANSPARECY and THRESHOLD: Adjust detection for transparent or difficult products and set the sensor trigger level.
READY PER and SLOW PER: Set the count percentages at which the machine changes its feeding stage.
WIDE and BLOCK TIME: Set the accepted signal width and the temporary signal-blocking time.
WORK MODE: Select NORMAL for production. Use other modes only during commissioning or testing.
CH1 to CH16: Display the photoelectric response value for each channel.
CHANNEL ENABLE: Opens the individual channel enable page.
B Channel and System Check
 |  |
| Channel enable screen | System information screen |
Channel Enable: Touch the numbered buttons under IR1, IR2, IR3, and IR4 to enable or disable individual photoelectric channels. Disabled channels do not participate in counting. Check the counting accuracy after making any change.
System Info: Displays the controller, infrared module, LED and vibration versions, the number of channels, and the READY, SLOW, and SHAKE status indicators. Record these values when requesting technical support.
C Vibration and Bottle Settings
 |  |
| Vibrate setting screen | Bottle setting screen |
Vibrate Set: FIRST, SECOND, and THIRD set the three vibration stages for each channel. SLOW PER sets the reduced vibration value. Use the ON/OFF button to enable the corresponding row, then touch SAVE after adjustment.
Bottle Set: PASS DELAY, PASS MOVE1 to PASS MOVE4, and PASS2 MOVE set the commissioned bottle-transfer timing and movement values. With automatic operation stopped, use BOTTLE1 to BOTTLE4 to check the corresponding bottle lanes manually.
D Reject and Shake Settings
 |  |
| Abandon setting screen | Shake setting screen |
Abandon Set: REMOVE TIME, REMOVE DELAY1, and REMOVE DELAY2 set the reject timing. REMOVE ENABLE turns the reject function on or off.
Shake Set: DOWN TIME, UP TIME, and DELAY SET define the shake cycle. ENABLE turns the function on or off.
E Control and Gate Settings
 |  |
| Control setting screen | Gate setting screen |
Control: PLUG TIME, BOTTLE IN TIME, and NO GOODS TIME set the corresponding monitoring times. READY SLOW and AHEAD SLOW enable the related slow-feed functions.
Gate Set: GATE DELAY and GATE MOVE set the commissioned gate timing and movement values.
F Factory Settings Test and IO Check
 |  |
| Factory setting screen | Manual test screen |
Factory: SYS MODE, LED COUNT, VIBRATE CH, and the bottle selector must match the installed hardware. Only trained service personnel may change these values.
Test: Manually operates BOTTLE1 to BOTTLE4, GATE1 to GATE4, REMOVE1, UP, DOWN, and SHAKE1 to SHAKE4.

Input and output examination screen