Email Us
Table of Content [Hide]

    1 Main Technical Parameters

    ModelYL-32
    Production rate10-100 bottles/min
    Product rangeSize 5# to 00# capsules, soft capsules, Ø6-26 mm round tablets, shaped tablets, and sugar-coated tablets
    Count per bottle2-9999 pieces
    Vibration stages3
    Applicable bottles10-500 mL round or square bottles (standard discharge-port diameters: 22 mm and 28 mm)
    Maximum bottle height≤160 mm
    Accuracy≥99.5%
    Hopper volumeApproximately 90 L
    Air pressure0.6 MPa
    Power supply / rated power380 V, 50 Hz / 1.3 kW
    NW/GW720 kg
    Machine dimensions (L × W × H)240 × 180 × 170 cm
    RemarksProduction speed depends on the product type, size, specification, and count per bottle.


    2 Machine Structure

    Machine Frame — The machine frame supports the electromagnetic vibrators, vibrating trays, hopper, conveyor, and related assemblies. The electrical control system is installed inside the cabinet.

    Conveyor — The conveyor feeds bottles continuously through the counting station. Use the speed control on the right side to adjust the conveyor speed and to start or stop the conveyor as required. In an emergency, press the emergency-stop switch beside the conveyor to stop the machine. To suit different bottle heights, loosen the fixing bolts on the two triangular supports below the conveyor, adjust the conveyor height, and retighten the bolts.

    Electromagnetic Vibrator — The electromagnetic vibrators spread and separate the product as it moves from the hopper toward the counting channels. The machine has two vibrator groups.

    Control Panel — The control panel is installed on the right side of the cabinet. Use the touchscreen to set operating parameters, start or stop the machine, monitor operation, and check alarms.

    The main machine components are shown below:


    1

    Infeed hopper

    2

    Electromagnetic vibrating trays

    3

    Touch screen

    4

    Emergency-stop switch

    5

    Bottle-stop solenoid valve

    6

    Conveyor

    7

    Machine frame

    8

    Adjustable foot

    9

    Photoelectric sensor

    10

    Discharge port

    11

    Lifting mechanism

    12

    Bottle-presence sensor

    The counting-channel arrangement is shown below:



    3 Parameter Settings

    Connect the power supply and turn on the main power switch. The main control screen appears as shown below.


    Main control screen


    01. COUNT SET: Sets the required number of pieces per bottle.

    02. YIELD: Displays the accumulated production quantity. Stop the machine before touching YIELD RST to reset the value.

    03. SPEED: Displays the current production speed in bottles per minute.

    04. COUNT1 to COUNT4: Display the count for each lane. Stop the machine before touching COUNT RST to reset the lane counters.

    05. START: Starts automatic operation.

    06. STOP: Stops automatic operation.


    Main screen controls and menu

    07. VIBRATE+ and VIBRATE-: Fine-tune the feed vibration output.

    08. RUN, ALARM, and ESTOP BLOCK: Display the running, alarm, and emergency-stop interlock status.

    09. CONVEYOR: Turns the conveyor command on or off.

    10. SYSTEM, MENU, TEST, EXAMINE, and RECIPE: Open the corresponding pages from the bottom navigation bar.

    11. CHINESE and ENGLISH: Change the HMI display language.

    12. MENU: Touch MENU to open the parameter selection page shown below.


    Menu screen


    Select IR, VIBRATE, BOTTLE, ABANDON, SHAKE, CONTROL, GATE SET, or FACTORY to open the required setting page. Touch SAVE after making an approved parameter change.


    A IR Settings

    IR setting screen


    FILTER: Filters short or unwanted sensor signals. Adjust this value only after checking the counting accuracy.

    TRANSPARECY and THRESHOLD: Adjust detection for transparent or difficult products and set the sensor trigger level.

    READY PER and SLOW PER: Set the count percentages at which the machine changes its feeding stage.

    WIDE and BLOCK TIME: Set the accepted signal width and the temporary signal-blocking time.

    WORK MODE: Select NORMAL for production. Use other modes only during commissioning or testing.

    CH1 to CH16: Display the photoelectric response value for each channel.

    CHANNEL ENABLE: Opens the individual channel enable page.

    B Channel and System Check


    Channel enable screenSystem information screen


    Channel Enable: Touch the numbered buttons under IR1, IR2, IR3, and IR4 to enable or disable individual photoelectric channels. Disabled channels do not participate in counting. Check the counting accuracy after making any change.

    System Info: Displays the controller, infrared module, LED and vibration versions, the number of channels, and the READY, SLOW, and SHAKE status indicators. Record these values when requesting technical support.


    C Vibration and Bottle Settings

    Vibrate setting screenBottle setting screen


    Vibrate Set: FIRST, SECOND, and THIRD set the three vibration stages for each channel. SLOW PER sets the reduced vibration value. Use the ON/OFF button to enable the corresponding row, then touch SAVE after adjustment.

    Bottle Set: PASS DELAY, PASS MOVE1 to PASS MOVE4, and PASS2 MOVE set the commissioned bottle-transfer timing and movement values. With automatic operation stopped, use BOTTLE1 to BOTTLE4 to check the corresponding bottle lanes manually.


    D Reject and Shake Settings

    Abandon setting screenShake setting screen


    Abandon Set: REMOVE TIME, REMOVE DELAY1, and REMOVE DELAY2 set the reject timing. REMOVE ENABLE turns the reject function on or off.

    Shake Set: DOWN TIME, UP TIME, and DELAY SET define the shake cycle. ENABLE turns the function on or off.


    E Control and Gate Settings

    Control setting screenGate setting screen


    Control: PLUG TIME, BOTTLE IN TIME, and NO GOODS TIME set the corresponding monitoring times. READY SLOW and AHEAD SLOW enable the related slow-feed functions.

    Gate Set: GATE DELAY and GATE MOVE set the commissioned gate timing and movement values.


    F Factory Settings Test and IO Check

    Factory setting screenManual test screen


    Factory: SYS MODE, LED COUNT, VIBRATE CH, and the bottle selector must match the installed hardware. Only trained service personnel may change these values.

    Test: Manually operates BOTTLE1 to BOTTLE4, GATE1 to GATE4, REMOVE1, UP, DOWN, and SHAKE1 to SHAKE4.


    Input and output examination screen


    Examine: Displays the status of IN1 to IN8 and OUT1 to OUT35 for troubleshooting. Touch SAVE after each approved adjustment. Touch BACK to return to the previous page.


    4 Equipment Maintenance

    Daily maintenance helps keep the machine operating correctly, reduces failures, and extends its service life. Operators and maintenance personnel must follow the assigned maintenance responsibilities and report abnormal conditions promptly.


    5 Cleaning and Lubrication

    1 Cleaning

    1.1 Mechanical Parts

    Clean mechanical parts with alcohol and a clean cloth. Before cleaning, switch off and isolate the machine. Remove the parts in the following order:

    Hopper cover plate, discharge port, photoelectric box, hopper, electromagnet assembly, vibration side plate, first vibration plate, second vibration plate, and third vibration plate (optional).

    After cleaning, reinstall the parts in the reverse order and confirm that all fasteners and guards are secure.

    1.2 Electrical Components

    Electrical components normally require only dust removal. Do not allow water or cleaning liquid to contact any electrical component. If necessary, wipe the touchscreen, counter windows, and indicator lights with a clean, dry cloth.

    1.3 Sensors

    Sensors are sensitive electronic components. Clean the photoelectric sensors and pressure-switch windows with a clean, dry cloth.

    1.4 Pneumatic Components

    The air inlet is fitted with a filter that removes moisture and dirt from the compressed-air supply. Drain and service the filter regularly to maintain reliable pneumatic operation.

    Cylinder Cleaning

    Wipe the cylinder and piston rod with a clean, dry cloth. Apply a few drops of approved pneumatic oil to the piston rod.

    Valve Cleaning

    Do not disassemble valves for cleaning. Contact the manufacturer for valve servicing or replacement.

    Warning: Dust and condensed water can shorten the service life of pneumatic components.

    Before cleaning pneumatic components, disconnect the machine from the compressed-air supply and release the remaining pressure.

    2 Lubrication

    Only qualified maintenance personnel may lubricate the machine. Follow the intervals and lubricant requirements in the table below.

    Lubrication point

    Method

    Interval

    Lubricant

    Drive chain

     

    Manual lubrication

    1 month

    Lubricating oil (0-35 °C)

    3 months

    Lubricating grease (>35 °C or <0 °C)

    Adjustment screw and guide rod

    Manual lubrication

    1 month

    Lubricating oil (0-35 °C)

    3 months

    Lubricating grease (>35 °C or <0 °C)


    6 Inspection and Repair

    During operation, monitor the machine and record any abnormal condition. If an abnormal condition occurs, stop the machine immediately and notify maintenance personnel. Restart the machine only after the fault has been identified and corrected.

    Qualified maintenance personnel must inspect and service the machine at the specified intervals.

    Before maintenance, disconnect and isolate the electrical power and compressed-air supply. Follow all applicable safety procedures. If a fixed guard must be opened or removed, reinstall it correctly before returning the machine to service.

    The recommended maintenance schedule is shown below.

     


     

    Maintenance target

    Interval

    Two weeks after commissioning

    Every 2 weeks

    Every month

    Every 3 months

    As required

    Drive chain

    Adjust / set


    Inspect / maintain


    Replace

    Adjustment mechanism


    Inspect / maintain



    Replace

    Guide and actuator


    Inspect / maintain



    Replace

    Bearing




    Inspect / maintain

    Replace

    Electrical system



    Inspect / maintain


    Replace

    Pneumatic system



    Inspect / maintain


    Replace

    Safety devices



    Inspect / maintain


    Replace

    Other components




    Inspect / maintain

    Replace


    7 Electrical Component Maintenance

    ①.Once a week, isolate the electrical supply and remove dust from the electrical control cabinet with a suitable dry cleaning method.

    ② Every two weeks, check that electrical terminals are secure. Tighten loose terminals using the correct tools and torque to prevent poor contact.

    ③ Check motor cables for damaged insulation or other defects. Replace damaged cables immediately to prevent short circuits and electric shock.


    References
    Related Pharmaceutical Equipment News
    Products
    Contact


    +86-15140990256

    YL-32 Electronic Counting Machine User Manual

    +86-13941977284

    YL-32 Electronic Counting Machine User Manual


    Dongxing Road, Baita District, Liaoyang City, Liaoning Province, China
    Yagang Road, Changzhou City, Jiangsu Province
    Zhoutie Town, Yixing City, Jiangsu Province
    Shuxi Road, Wucheng District, Jinhua City, Zhejiang Province
    Dongxing Road, Baita District, Liaoyang City, Liaoning Province, China
    Yagang Road, Changzhou City, Jiangsu Province
    Zhoutie Town, Yixing City, Jiangsu Province
    Shuxi Road, Wucheng District, Jinhua City, Zhejiang Province